iir

iir — iir digital filter

Calling sequence

[hz]=iir(n,ftype,fdesign,frq,delta)  

Parameters

n : filter order (pos. integer)
ftype : string specifying the filter type 'lp','hp','bp','sb'
fdesign : string specifying the analog filter design ='butt','cheb1','cheb2','ellip'
frq : 2-vector of discrete cut-off frequencies (i.e., 0<frq<.5). For lp and hp filters only frq(1) is used. For bp and sb filters frq(1) is the lower cut-off frequency and frq(2) is the upper cut-off frequency
delta

: 2-vector of error values for cheb1, cheb2, and ellip filters where only delta(1) is used for cheb1 case, only delta(2) is used for cheb2 case, and delta(1) and delta(2) are both used for ellip case. 0<delta(1),delta(2)<1

- for cheb1 filters 1-delta(1)<ripple<1 in passband
- for cheb2 filters 0<ripple<delta(2) in stopband
- for ellip filters 1-delta(1)<ripple<1 in passband and 0<ripple<delta(2) in stopband

Description

function which designs an iir digital filter using analog filter designs.

Examples



hz=iir(3,'bp','ellip',[.15 .25],[.08 .03]);
[hzm,fr]=frmag(hz,256);
plot2d(fr',hzm')
xtitle('Discrete IIR filter band pass  0.15<fr<0.25 ',' ',' ');
q=poly(0,'q');     //to express the result in terms of the ...
hzd=horner(hz,1/q) //delay operator q=z^-1
 
  

See also

eqfir, eqiir

Author

C. B.